你好,欢迎光临济南兰鑫厨房排烟!

产品中心

厨房排烟是日常环保的“重中之重”

来源:http://www.jnlxcfpy.com/添加时间:2018-08-13 14:22:37
1、修整楼板预留洞(大的偏差通知土建方打凿),首先弹出楼板预留洞的中心线,以中心线为基准按予留洞尺寸要求修整。
1. Dressing the slab reserved holes (large deviation notification of civil excavation), first pop up the center line of the slab reserved holes, with the center line as the benchmark according to the size requirements of the hole.
2、依据安装图对各层管道进行分配。
2, according to the installation diagram, the distribution of each tier of pipelines is carried out.
3、从下至上逐层安装,调整好垂直度后,临时用砼块将排风道固定。
3. Install the exhaust duct layer by layer from bottom to top. After adjusting the verticality, fix the exhaust duct temporarily with concrete blocks.
4、对上下两根排气管接口处用胶拌素水泥浆,按0.05:1重量比混合砂浆刮涂于管端对正座严。
4. Use glue-mixed plain cement slurry at the joints of the upper and lower exhaust pipes. Scrape and apply the mixed mortar at the end of the pipe with 0.05:1 weight ratio.
5、厨房等截面排气道,每5层做一次承托处理。
5, the kitchen section of the exhaust section, every 5 layers of a bearing treatment.
6、分段工程完成后,对垂直度、进气口高度、管体质量进行检查。
6. After the completion of the subsection works, check the verticality, intake height and pipe quality.
济南厨房设备
7、分段完工后,进行管口遮盖,防止杂物掉入管道内。
7, after the completion of the section, the pipe will be covered to prevent debris from falling into the pipeline.
8、因排气道为薄壁构件,在搬动和安装时均应轻抬轻放,不得冲击碰撞,并不得在管道上堆放重物和行走。如有局部损伤,在不影响使用效果前提下,可用1:2水泥砂浆加5%胶水现场修补。
8. Because the exhaust duct is a thin-walled component, it should be lightly lifted and lightly placed when moving and installing. It is not allowed to impact and collide, and heavy objects and walk on the pipeline are not allowed. If there is local damage, it can be repaired with 1:2 cement mortar and 5% glue on the premise of not affecting the use effect.
9、系统完工后就对系统进行自检。
9, after the system is completed, the system is self tested.
10、排烟管道请勿往下水道排,这样做结果往往是厨房排烟不畅,餐厅无法正常营业,而后停业改造通风系统。
10. Do not drain the smoke pipe into the sewer. The result is often that the kitchen smoke exhaust is not smooth, the restaurant can not operate normally, and then shut down to reform the ventilation system.
11、小区、大厦开餐厅不能做管道的,一定要慎重,油烟净化设备供应商要有足够的能力和实力做好油烟净化工程。
11. If a restaurant in a residential area or building can not be opened as a pipeline, it must be prudent. The supplier of lampblack purification equipment should have sufficient capacity and strength to do a good job in lampblack purification project.

上一篇:通风管道道在加工容易出现哪些质量不合格因素?
下一篇:厨房排烟管道风机什么标准才算好用?

济南兰鑫厨房排烟    电话:15610162918    地址:济南市天桥区联四路167号
本网站由济南诺商提供技术支持      