  通风管道施工技术施工非专业厂家不能达到要求,通风管道厂家都有自己的一套施工标准,对于不同时期及要求的施工,通风管道厂家更是严格执行这样的标准。
  Ventilation and pipeline construction technology can not meet the requirements of non professional manufacturers. Ventilation pipe manufacturers have their own set of construction standards. For different periods and requirements of construction, ventilation pipe manufacturers strictly enforce such standards.
  通风管道绝热工程施工技术质量要求:
  The construction technology quality requirements of ventilation pipe insulation engineering are:
  1、空调工程的制冷系统管道,包括制冷设备和空调水系统绝热工程的施工,应在管路系统强度与严密性检验合格和防腐处理结束后进行。
  1, the construction of refrigeration system piping, including refrigeration equipment and air conditioning water system, should be carried out after pipeline system strength and tightness check and the end of anticorrosion treatment.
  2、管道保温前,要求先清理干净管道表面污染物,后进行保温材料的施工,避免胶水粘接力不够,保温材料粘结开裂。
  2, before pipeline insulation, it is required to clean up the contaminants on the surface of pipes first, and then carry out the construction of thermal insulation materials, so as to avoid glue adhesion and thermal insulation materials.
济南厨房排烟管道
  3、施工人员必须按照施工技术交底进行施工,加强质量意识,严格按照施工工艺及质量标准进行施工。
  3, the construction personnel must carry out the construction according to the construction technology, strengthen the quality consciousness, strictly follow the construction technology and quality standards.
  4、保温胶水宜均匀的涂在管道、部件或设备的外表面上,绝热材料与管道、部件及设备表面应紧密贴合,无空隙。
  4, the insulation glue should be evenly coated on the outer surface of pipes, components or equipment. The insulation materials should be closely linked to the surface of pipes, components and equipment, without gaps.
  5、绝热层纵横向的接缝,应错开。
  5. The longitudinal and transverse joints of the adiabatic layer should be staggered.
  6、所有接口和支撑的地方都必须用专用胶水粘接,以保证密封,防止跑冷,出现结露现象。
  6. All interfaces and supporting places must be bonded with special glue to ensure sealing, prevent cold and appear condensation.
  7、施工保温前要确认管套规格是否保温管相符,避免出现偏大或偏小现象。
  7, before the construction of insulation to confirm whether the pipe jacket specifications are consistent with the insulation, to avoid large or small phenomenon.
  8、安装后所有的三通、弯头、阀门、法兰和其他附件都需要达到设计厚度。
  8. All three connections, elbows, valves, flanges and other accessories after installation are required to reach the design thickness.
  本文的精彩内容来自济南厨房排烟管道详细内容请点击我们的官方网站:http://www.jnlxcfpy.com/谢谢您的到来!